FC Series - 50Hz / 60Hz / 400Hz 2KVA To 2.5KVA

Features
  Test Source for American Line Powered equipment or for Airlines
  Maintenance Work Shops.
  115V, 60Hz or 115V, 400Hz Output Power.
  Upto 7.5KVA Capacity.
  High Efficiency - 85% Approx.
  Sinewave Output with Less Than 3% Distortion.
  Delivers upto 200% Overload for a Cycle.
  Delivers Full Power in 45°C Ambient Environment.
  IGBT based PWM Technology.
  Compact, Light Weight Construction.
Frequency Converter 2 to 7.5KVA
 
With increasing Global trade, manufacturers in India need to test equipment on commercial line supply available in those countries. Equipment exported to several countries require 115V supply at 60Hz. Equipment used by aircraft industry needs 115V supply at 400Hz. Aplab is the largest manufacturer and exporter of Frequency Converters upto 100KVA capacity in single phase & 200KVA in 3 phase category.
An Aplab Frequency Changer consists of a Rectifier and a Static Inverter. The Rectifier converts the commercial AC power to very precise DC power and supplies the Static Inverter. The IGBT-based Pulse Width Modulation (PWM) technology is used to convert DC power to a very precise low distortion Sine-wave output at very high efficiency.
 
Technical Specifications
MODEL  
FC-2
FC-3
FC-5
FC-7.5
Rated Power  
2.0KVA
1.6KW
3.0KVA
2.4KW
5.0KVA
4.0KW
7.5KVA
6.0KW
Input Voltage
195 Volts to 265 Volts, Single Phase.
Frequency
50Hz ± 3Hz.
AC-AC Efficiency
80% (approx.)
85% (approx.)
Output Voltage
115 Volts AC, Single Phase.
Regulation
±1% (typical).
Current
17.4 Amps
26.0 Amps
43.5 Amps
65.2 Amps
Frequency
60Hz for FC98-x/60 and 400Hz for FC98-x/400.
Frequency Stability
±0.5%.
Waveform
Sinewave.
Distortion
<3% on Linear loads.
Transient Response
±5% for 100% load variation; Recovery in 2 to 3 cycles.
Load Power Factor
Unity to 0.8 lag within maximum specified output power limits.
Short-term Overload
110% for 30 mins; 150% for 10 secs.; 200% for 5 cycles.
General Protections
Mains Over/Under Voltage, Output O/U Voltage, DC O/U Voltage, Output Overload, Overheat, Built-in soft-start, Snubber for Devices.
LED Indications
Mains On, DC On, Output On, Mains Over/Under Voltage. Output O/U Voltage, DC O/U Voltage, Output Overload, Overheat.
Metering
Analog meter to measure the AC Voltage & AC Current.
Digital meter to measure the Frequency.
Isolation
The FC Output is isolated from the Mains Input.
Protection Class
IP21.
Finish
DA Gray IS632.
Weight (in Kgs.)
68
77
88
114
Dimensions
(W x D x H) (mm)
300 x 600 x 640
300 x 600 x 640
375 x 600 x 720
375 x 600 x 720
Environment Temperature
0°C to 45°C (50°C peak).
Humidity
0 to 95% non-condensing at 30°C.
 
Selection Chart
Model
Output
Frequency
Voltage
Power
60Hz Models
FC-2/60
60Hz
115 Volts
2.0 KVA
FC-3/60
60Hz
115 Volts
3.0 KVA
FC-5/60
60Hz
115 Volts
5.0 KVA
FC-7.5/60
60Hz
115 Volts
7.5 KVA
400Hz Models
FC-2/400
400Hz
115 Volts
2.0 KVA
FC-3/400
400Hz
115 Volts
3.0 KVA
FC-5/400
400Hz
115 Volts
5.0 KVA
FC-7.5/400
400Hz
115 Volts
7.5 KVA
* All above models are available with battery back-up on request.