Tel. : 91-022-25821861
Fax : 91-022-25823137
Email : response@aplab.com
|
|
 |
| POWER FACTOR CORRECTED DC POWER SUPPLY - PF Series |
|
| Features |
 |
High Power – upto 30KW with 24 to 110V DC and 20 to 1200A Range |
 |
19" Rack Construction |
 |
Power Factor Corrected (0.99 at full load) Input |
 |
Wide Input Range |
 |
Equal Current Sharing Parallel Operation for upto 12 Nos. |
 |
Abnormal Condition Alarm |
 |
Output Boost Facility |
 |
7 Segment Display for Voltage and Current Measurement |
 |
n + 1 redundancy |
 |
Upgradable |
|
|
| |
The PF Series Switching DC Power Supply, is Power Factor corrected, designed to deliver variable DC power upto 30KW in a constant voltage mode. It covers a current range from 20A to 1200A, in Four Voltage Settings (30KW max). Higher rated power supplies can also be supplied against specific requirements. |
This range comes, housed in 19" rack mounting construction, with modules in multiples of 2.5KW each which can be connected in n+1 configuration with equal current sharing parallel operation of upto 12 modules. The DC Output power can be upgraded by adding modules on to the rack at a later stage. This provides maximum flexibility to the user to plan for future & order modules at a later stage. |
The PF series power supply is used to simultaneously supply the DC load and recharge the battery. This type of DC system is widely used in Power Generation and Distribution, Instrumentation, Onshore and Offshore Petro-chemical applications etc. |
|
| |
| Technical Specifications |
| INPUT |
| Voltage |
176 - 265 V AC, 1ph, 2w (2 .5KW - 7.5kw)
305 - 465 3ph, 4w (above 7.5KW). |
| Frequency |
45 - 65 Hz. |
| Power Factor |
0.99 (at full load). |
| Spikes |
VDE 0843/IEC801-V-3-3. |
| Burst |
VDE 0843/IEC0801-IV-3-2. |
| RFI |
VDE 0878/EN55022-A. |
| OUTPUT |
| Voltage |
24V / 48V / 60V / 110V. |
| Line / Load Regulation |
Better than ±2%. |
| Ripple |
<200mV p-p. |
| Current |
20 Amps to 1200 Amps (any one rating). |
| Power |
2.5KW to 30KW max. |
| Recovery Time |
1ms typical. |
| Parallel Operation |
One or more units can be used in parallel for higher power capacity. |
| METERING |
7 Segment Display for Voltage and Current Measurement. |
| PROTECTIONS |
Over Voltage
& Over Temp : Electronic turn off for Output Over-voltage and
Over-temperature, Reset through panel push switch DC Overload. |
| INDICATIONS |
LED Green = Float.
LED Red = Boost. LED Red = Output Abnormal.
7 Segment DPM for Output Voltage & Current measurement. |
| COLOR |
DA Grey. |
| GENERAL DATA |
| Operating Temp. |
0ºC to +60ºC. |
| Derating |
2.5% / ºC above +40ºC. |
| Storage Temp. |
-20ºC to +70ºC. |
| Humidity |
90% without condensation. |
| Cooling |
Fan cooled with air exhaust at the rear. |
| Mech. Construction |
19" x 4 unit high x 500 mm deep. |
| Encl. Protection |
IP-20. |
| Connector |
Terminal strip for input. Brass terminals for output at the rear. |
| Weight |
Approx. 18 Kg. per module. |
|
| |
O/P Voltage VDC |
Current Amps |
Nominal |
Range |
24 |
23-28 |
100 |
200 |
300 |
600 |
900 |
1200 |
48 |
46-56 |
50 |
100 |
150 |
300 |
450 |
600 |
60 |
58-70 |
40 |
80 |
120 |
240 |
360 |
480 |
110 |
100-130 |
20 |
40 |
60 |
120 |
180 |
240 |
|
| |
|