Tel. : +91-22-67395555, 25821861
Fax : +91-22-25823137
Email : response@aplab.com
|
|
 |
| KILOWATT DC REGULATED SUPPLIES - SP Series |
|
| Features |
 |
Highest Power
Maximum Power of 150KW upto 2000A and 450VDC |
 |
Droop Setting
Facility via Front Panel Potentiometer |
 |
Man Machine Interface
User Friendly Controls and Instant Access to Status |
 |
6/12 Pulse Technology
Fully Controlled Rectifier |
 |
Wide Input Range
Suitable for Indian Power Scene |
 |
Unique Protection
Re-entrant / Shut-off Type for Overload / Short Circuit |
 |
Flexible Design
14 Models to Choose |
 |
Application Oriented
For Use in Aviation, Automobile, Process and Engineering Industry |
|
|
| |
The Special Purpose - SP Series is specifically designed, keeping in mind the expectations of end user for simulation of battery characterestics through provision of Droop setting facility. The series has been evolved for the purpose of testing of battery operated equipment, as well as Motors. Certain equipment/motors draw very high current during startup, thereby dropping the terminal voltage of the battery, due to its internal resistance. The series can deliver very high inrush current without tripping, due to Re-entrant type characterestics. As the inrush current starts falling, the output voltage starts building up and reaches the set level. |
| |
| Technical Specifications |
| INPUT |
| Voltage |
415V AC ±10% (upto ±30% on request), 50Hz ±6%, 3Ø, 4 wire or 3Ø, 3 wire.
Optional 230V AC ±10%, 1Ø, 2 wire-upto power level of 5KW. |
| OUTPUT |
| Voltage |
4 to 16V DC or 6 to 32V DC (any one voltage range). |
Line / Load Regulation |
±1% of rated O/P Voltage. |
| Ripple |
1% rms of rated O/P Voltage. |
| Current |
50A to 2000A Max. (any one rating). |
| Droop Facility |
Source resistance can be varied from 2Mohms to 20 ohms. |
| Power |
150KW Max. |
Cabinet Encl. Protection |
IP-20, Optional (IP-21, IP-30, IP-31 or IP-40). |
| Cooling |
Forced Air Cooling. |
| Cabinet Color |
D.A. Grey. |
| Metering |
Analogue Meters for Output Voltage / Output Current.
Optional Input Voltage / Input Current.
Optional Digital Meters. |
| Protections |
Input Over/Under
Voltage, Phase Fail/Reversal (for 3 phase input), Output DC Overload/Shortcircuit,
Output DC Over voltage, Overheat, Soft-Start Feature, High Speed Fuses for Semi-Conductor Devices and Snubber Circuits for
power Semi-Conductor Devices. |
| Indications |
Mains ON, DC ON, Phase Fail (for 3 phase input), Mains Over/Under Voltage, DC Over/Under Voltage, DC Overload and Overheat. |
| Application |
Widely used in the testing of Battery operated equipment / Motors. |
|
| |
| Selection Guide |
V / I |
50A |
100A |
300A |
500A |
1000A |
1500A |
2000A |
16 |
16-50 |
16-100 |
16-300 |
16-500 |
16-1000 |
16-1500 |
16-2000 |
32 |
32-50 |
32-100 |
32-300 |
32-500 |
32-1000 |
32-1500 |
32-2000 |
| Other ratings on request upto 450V DC, 2000A with max. power of 150KW. |
|
| |
|