Tel. : 91-022-25821861
Fax : 91-022-25823137
Email : response@aplab.com
|
|
 |
2 TO 7.5KVA FREQUENCY CONVERTER - FC98 Series
50Hz IN / 60Hz OUT OR 400Hz OUT |
|
| Features |
 |
Test Source for American Line Powered equipment or for Airlines. |
 |
Maintenance Work Shops. |
 |
115V, 60Hz or 115V, 400Hz Output Power. |
 |
Upto 7.5KVA Capacity. |
 |
High Efficiency - 85% Approx. |
 |
Sinewave Output with Less Than 3% Distortion. |
 |
Delivers upto 200% Overload for a Cycle. |
 |
Delivers Full Power in 45°C Ambient Environment. |
 |
IGBT based PWM Technology. |
 |
Compact, Light Weight Construction. |
|
|
| |
With increasing Global trade, manufacturers in India need to test equipment on commercial line supply available in those countries. Equipment exported to several countries require 115V supply at 60Hz. Equipment used by aircraft industry needs 115V supply at 400Hz. Aplab is the largest manufacturer and exporter of Frequency Converters upto 100KVA capacity in single phase & 200KVA in 3 phase catagory. |
An Aplab Frequency Changer consists of a Rectifier and a Static Inverter. The Rectifier converts the commercial AC power to very precise DC power and supplies the Static Inverter. The IGBT-based Pulse Width Modulation (PWM) technology is used to convert DC power to a very precise low distortion Sine-wave output at very high efficiency. |
|
|
| Technical Specifications |
| MODEL |
|
FC98-2 |
FC98-3 |
FC98-5 |
FC98-7.5 |
| Rated Power |
|
2.0KVA
1.6KW |
3.0KVA
2.4KW |
5.0KVA
4.0KW |
7.5KVA
6.0KW |
| Input |
Voltage |
195 Volts to 265 Volts, Single Phase. |
| Frequency |
50Hz ± 3Hz. |
| AC-AC Efficiency |
80% (approx.) |
85% (approx.) |
| Output |
Voltage |
115 Volts AC, Single Phase. |
| Regulation |
±1% (typical). |
| Current |
17.4 Amps |
26.0 Amps |
43.5 Amps |
65.2 Amps |
| Frequency |
60Hz for FC98-x/60 and 400Hz for FC98-x/400. |
| Frequency Stability |
±0.5%. |
| Waveform |
Sinewave. |
| Distortion |
<3% on Linear loads. |
| Transient Response |
±5% for 100% load variation; Recovery in 2 to 3 cycles. |
Load Power Factor |
Unity to 0.8 lag within maximum specified output power limits. |
| Short-term Overload |
110% for 30 mins; 150% for 10 secs.; 200% for 5 cycles. |
| General |
Protections |
Mains Over/Under Voltage, Output O/U Voltage, DC O/U Voltage, Output Overload, Overheat, Built-in soft-start, Snubber for Devices. |
| LED Indications |
Mains On, DC On, Output On, Mains Over/Under Voltage. Output O/U Voltage, DC O/U Voltage, Output Overload, Overheat. |
| Metering |
Analog meter to measure the AC Voltage & AC Current.
Digital meter to measure the Frequency. |
| Isolation |
The FC Output is isolated from the Mains Input. |
| Protection Class |
IP21. |
| Finish |
DA Gray IS632. |
| Weight (in Kgs.) |
68 |
77 |
88 |
114 |
Dimensions
(W x D x H) (mm) |
300 x 600 x 640 |
300 x 600 x 640 |
375 x 600 x 720 |
375 x 600 x 720 |
| Environment |
Temperature |
0°C to 45°C (50°C peak). |
| Humidity |
0 to 95% non-condensing at 30°C. |
|
|
| Selection Chart |
Model |
Output |
Frequency |
Voltage |
Power |
60Hz Models |
FC98-2/60 |
60Hz |
115 Volts |
2.0 KVA |
FC98-3/60 |
60Hz |
115 Volts |
3.0 KVA |
FC98-5/60 |
60Hz |
115 Volts |
5.0 KVA |
FC98-7.5/60 |
60Hz |
115 Volts |
7.5 KVA |
400Hz Models |
FC98-2/400 |
400Hz |
115 Volts |
2.0 KVA |
FC98-3/400 |
400Hz |
115 Volts |
3.0 KVA |
FC98-5/400 |
400Hz |
115 Volts |
5.0 KVA |
FC98-7.5/400 |
400Hz |
115 Volts |
7.5 KVA |