UPS SYSTEMS 35KVA TO 60KVA - MP Series
3 Phase in / 3 Phase out

Features
35-60KVA in 4 Ratings.
Can Feed 100% Unbalanced Load and Still Maintain ±1% Regulation Per Phase.
Sophisticated High Specification On Line Configuration with Optional Static Switch.
State of the Art IGBT Based Pulse Width Modulation (PWM) Technology to Reduce Harmonic Distortion and Increase Both Crest Factor Tolerance and Dynamic Stability.
Higher Efficiency of Operation Means Aplab UPS has Significantly Lower Running Costs than Leading Competitors.
Continuously Delivers Full Rated Power at Ambient as high as 45ºC.
Parallel Operation of UPS.
Comprehensive Indication of Normal and Fault Conditions.
Excellent Unbalanced Line & Load Performance.
Compatible with Sealed Maintenance Free Battery as well as Tubular Lead Acid Batteries.
Compact Cabinet & Ultra Light Weight.
Easy Installation with Wheels for Manoeuvreability and Front Terminal Box.
Optional Remote Status Panel.
Aplab 35KVA to 60KVA UPS
 
Technical Specifications
MODEL
MP3035
MP3040
MP3050
MP3060
RATED POWER (at PF 0.8)
35KVA
40KVA
50KVA
60KVA
INPUT
Voltage Nominal
               Range
400V AC
340V AC to 460V AC.
Frequency Nominal
                    Range
50Hz.
47 to 53Hz.
Phase
Three Phase, 4 Wire.
AC to AC Efficiency
>88% peak
>89% peak
OUTPUT
Power Max.
35KVA/28KW
40KVA/32KW
50KVA/40KW
60KVA/48KW
Current
50.7 Amps.
58.0 Amps.
72.4 Amps.
87.0 Amps.
Voltage
400V AC.
Voltage Regulation
±1% Typical.
Frequency
50Hz.
Frequency Stability
±0.05%.
Phase
Three Phase & Neutral.
Waveform
Sinewave.
Total Harmonic Distortion
Less than 2% with Linear Load.
TRANSIENT RESPONSE
(100% Load Step)
Less than ±5%.
RESPONSE TIME
Less than 60 milli-seconds to reach within ±2%.
LOAD POWER FACTOR RANGE
Unity to 0.8 Lag within specified max. output power ratings.
OVERLOAD RATING a) 1/2 Hour
b) 10 Seconds
c) 10 Cycles
120%
150%
200%
VOLTAGE BALANCE
(Balanced Load)
±1%.
100% UNBALANCED LOAD
±3%.
PHASE DISPLACEMENT
120º ±3º
PROTECTIONS a) Input Over/Under Voltage
b) Phase Fail
c) Overload at the Output
d) SOAR Protection for IGBTs
e) Output AC Over/Under voltage
g) High Speed Fuses for Semi-Conductor Devices
h) Snubber Circuits for Power Semi-Conductor Devices
INDICATIONS a) Mains On
b) Inverter On
c) Battery on Charge
d) Mains Over/Under Voltage
e) Phase Fail
f) Low Battery Imminent
g) Battery Over/Under Voltage
h) Inverter Over/Under Voltage
i) Inverter Overload
j) Overheat
AUDIBLE ALARM
For Conditions from (d) to (j) a Local Buzzer operates.
REMOTE INDICATIONS
A potential free contact is provided for fault indications and alarm.
COMPUTER INTERFACE
RS-232 (Optional).
METERING 16 x 2 LCD to measure the following :
a) AC Input/Output Voltage per Phase
b) Load Percentage
c) DC Voltage
d) Battery Percentage
e) Output Frequency
BATTERY
Nominal Voltage
384V DC.
Type
Sealed maintenance free / tubular lead Acid Battery.
Standby Period
(Full Load at 0.8 PF)
30 Minutes
(can be increased upto 2 hrs and extended further on request).
GENERAL
Operating Temperature
0 to 45ºC.
Storage
-20ºC to +65ºC.
Finish
Cool Grey Shade No. 5-C & 1-C.
Relative Humidity
Non Condensing
0 to 95%.
Enclosure Protection
IP20.
Dimensions  HEIGHT
                         WIDTH
                         DEPTH
1350 mm
800 mm
550 mm
1500 mm
900 mm
600 mm
1550 mm
900 mm
650 mm
1550 mm
900 mm
650 mm
Weight
395 Kgs.
510 Kgs.
550 Kgs.
605 Kgs.
OPTIONAL STATIC SWITCH
Transfer Time a) Less than 5 milli-seconds from inverter to mains.
b) Less than 5 milli-seconds from mains to inverter.
Indications a) Aux. Supply On
b) Load on Inverter
c) Load on Aux. Supply
d) Manual Bypass On
 
 