Tel. : 91-022-25821861
Fax : 91-022-25823137
Email : response@aplab.com
|
|
 |
OPEN FRAME LINEAR POWER SUPPLIES
International Series Single, Dual or Triple Outputs -5V, 12V, 12W upto 200W
(Minimum Order Qty. 25 Nos. in each type) |
|
| Features |
 |
Input Voltage Options for All Countries |
 |
Industry Standard Sizes and Mounting |
 |
12 Hours Burn-in |
 |
Approved to UL1950, EN60950 and IEC-950, UL-FILE E192398 |
 |
Meets CISPER 22 Class B conducted emission limits |
 |
Approved to CE LVD |
 |
VDE Transformer Construction |
|
|
| |
The Global Standard series open frame linear power supplies are characterised by professional design and ruggedised construction. With input line voltage of 100 / 120 / 220 / 230 / 240V AC ±10% at 50 or 60Hz, these supplies can be used worldwide. |
The power transformer is designed with enclosed split bobbin construction and creepage distances as per VDE0730 requirements. The units have 3750V AC isolation. The global standard series are high efficiency conservatively designed units which undergo 12 hours burn-in tests before shipment. Efficiencies of over 60% reduce heat dissipation, thereby ensuring long operating life. |
Standard models are listed in Table. However special versions can be offered with output voltages between 2V and 32V DC and power output from 15 Watts to 150 Watts. |
|
| |
| Technical Specifications |
| All specifications typical at nominal line, full load and 25ºC unless otherwise noted. |
| OUTPUT |
|
| Output Voltage and Current |
See Selection Guide. |
| Output Voltage Adjustment Range |
±5%. |
| Load Regulation |
NL to FL : ±0.05% max. |
| Line Regulation |
±10%. |
| Input Change |
±0.05% max. |
| Output Ripple |
1mV rms max., 3mV p-p. |
| Temperature Coefficient |
0.01% per ºC. |
Transient Response,
50% FL Change |
50µsec max. |
Stability, 8 hours,
after warm-up |
±0.05%. |
| Short Circuit Protection |
Foldback current limiting automatic recovery. |
| Overvoltage Protection |
Crowbar, on 5V output (set at 6.2V ±0.4V optional for other outputs). |
| Remote Sensing |
Standard on all outputs (on main output, upto 0.5V drop. Open sense-lead protection built-in). |
| Reverse Voltage Protection |
Standard. |
| INPUT |
|
| Input Voltage |
100 / 120 / 220 / 230 / 240V AC. |
| Input Frequency |
47Hz - 63Hz. Derate 10% at 50Hz. |
| GENERAL |
|
Efficiency (Measured at
Normal Output +0.5V) |
5V outputs : 45%.
12V & 15V outputs : 55%
24V outputs : 60%. |
Break Down Voltage (Input
to Output or Input to Ground) |
3750V AC min. |
| ENVIRONMENTAL |
|
| Operating Temperature Range |
0ºC to 70ºC. |
| Derating, 50ºC to 70ºC |
3% per ºC. |
| Storage Temperature Range |
-25ºC to +85ºC. |
| PHYSICAL |
|
| Case Material |
Anodized Aluminium. |
| Options |
Remote sense on other outputs, OVP crowbar on other outputs, Remote shutdown, Screw type output terminals. |
|
| |
| Selection Guide |
|
Output 1 |
Output 2 |
Output 3 |
OVP |
Case |
Model |
Voltage |
Current |
Voltage |
Current |
Voltage |
Current |
SINGLE OUTPUT |
5V |
5V |
3.0A |
|
|
|
|
Yes |
B |
OFL10 |
5V |
6.0A |
|
|
|
|
Yes |
C |
OFL11 |
5V |
9.0A |
|
|
|
|
Yes |
N |
OFL12 |
5V |
12.0A |
|
|
|
|
Yes |
D |
OFL13 |
5V |
18.0A |
|
|
|
|
Yes |
E |
OFL14 |
12V |
12V |
1.8A |
|
|
|
|
|
B |
OFL20 |
12V |
3.4A |
|
|
|
|
|
C |
OFL21 |
12V |
6.8A |
|
|
|
|
|
D |
OFL22 |
12V |
10.2A |
|
|
|
|
|
E |
OFL23 |
24V |
24V |
1.2A |
|
|
|
|
|
B |
OFL40 |
24V |
2.4A |
|
|
|
|
|
C |
OFL41 |
24V |
4.8A |
|
|
|
|
|
D |
OFL42 |
DUAL OUTPUT |
±12V |
+12V |
+1.0A |
-12V |
-1.0A |
|
|
|
AA |
OFL50 |
+12V |
+1.8A |
-12V |
-1.8A |
|
|
|
BB |
OFL51 |
+12V |
+3.4A |
-12V |
--3.4A |
|
|
|
CC |
OFL52 |
TRIPLE OUTPUT |
±12V
±15V
& 5V |
5V |
3.0A |
±12V |
+1.0A |
-12V |
-1.0A |
Yes |
BB |
OFL70 |
5V |
6.0A |
±12V |
+1.8A |
-12V |
-1.8A |
Yes |
CBB |
OFL71 |
5V |
12.0A |
±12V |
+1.8A |
-12V |
-1.8A |
Yes |
DBB |
OFL72 |
5V |
3.0A |
±12V |
+0.8A |
-12V |
-0.8A |
Yes |
BB |
OFL80 |
5V |
6.0A |
±12V |
+1.5A |
-12V |
-1.5A |
Yes |
CBB |
OFL81 |
5V |
12.0A |
±12V |
+1.5A |
-12V |
-1.5A |
Yes |
DBB |
OFL82 |
|
| |
|